Sign In | Join Free | My himfr.com
Home > Large Room Precision Cooling >

Full Frequency Large Room Precision Cooling Units Modular Design

    Buy cheap Full Frequency Large Room Precision Cooling Units Modular Design from wholesalers
     
    Buy cheap Full Frequency Large Room Precision Cooling Units Modular Design from wholesalers
    • Buy cheap Full Frequency Large Room Precision Cooling Units Modular Design from wholesalers
    • Buy cheap Full Frequency Large Room Precision Cooling Units Modular Design from wholesalers

    Full Frequency Large Room Precision Cooling Units Modular Design

    Ask Lasest Price
    Brand Name : kimoems
    Model Number : Refer to parameters
    Certification : CE
    Payment Terms : T/T
    • Product Details
    • Company Profile

    Full Frequency Large Room Precision Cooling Units Modular Design

    Room-level Modular Full-frequency Energy-saving Precision Cooling


    Product Advantages
    • Full Inverter Regulation
      Fully variable speed design adjusts cooling capacity dynamically based on load; dual-system dual-inverter ensures precise load response, low starting current, and minimal impact on electrical equipment.
    • High Energy Efficiency
      High return air temperature design improves rated energy efficiency by over 40% compared to fixed frequency systems. Part-load operation enhances efficiency by 50% compared to fixed frequency systems, and annual energy efficiency improves by over 58%.
    • Safety and Reliability
      Full inverter design with low starting current reduces impact on power grids and UPS systems. Major components use internationally recognized brands, ensuring a Mean Time Between Failures (MTBF) of ≥100,000 hours.
    • Smart Fault Diagnosis
      Automatically analyzes potential fault causes when an alarm occurs, displays fault reasons on the interface, and guides maintenance personnel to resolve issues.
    • AI Energy Management
      Dynamically adjusts inverter components based on room load and ambient temperature changes for real-time efficiency. AI learns energy consumption patterns, optimizes settings, and uses group control to ensure efficient operation.
    • Flexible and Modular Design
      Fully modular design with independent modules for System 1, System 2, and control cabinets, simplifying transportation and on-site assembly.

    Full Frequency Large Room Precision Cooling Units Modular Design
    1. Electronic Expansion Valve
      Fast response, high control accuracy, real-time flow adjustment, efficient heat exchange in evaporator.
    2. Evaporator
      Hydrophilic fins, inner-grooved copper tubes, corrosion-resistant, long life, high efficiency.
    3. EC Fan
      Rear-inclined centrifugal fan with high efficiency, energy-saving, low noise, continuously adjustable airflow.
    4. Controller
      7-inch TFT color touchscreen, user-friendly interface, convenient operation.
    5. DC Inverter Scroll Compressor
      Variable displacement design, safe operation under varying conditions, high reliability, long life, low noise.
    6. Drier Filter
      High efficiency in acid removal, filtration, and drying, ensures reliable system operation.
    Parameters
    Dual-Inverter Series (R410A) Model (KMA.U(D)ESYVMRHGT/E) 301 351 401 451 501 601 702 802 902 1002 1102 1202
    Cooling Capacity 1












    Total Cooling Capacity kW 10.5-30.2 12.3-35.1 14.2-40.2 15.8-45.3 17.5-50.1 21.5-60.2 25-70.2 30-80.3 35-90.2 35-101.6 35-110.5 40-110.5 40-120.4
    Sensible Heat kW 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0
    Rated Cooling Capacity kW 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2
    Cooling Capacity 2












    Total Cooling Capacity kW 9.0-25.2 10.5-30.1 12.5-35.3 14.1-40.2 15.8-45.1 17.5-55.2 21.1-60.1 24.5-70.1 28.2-80.1 31.6-90.2 35.1-100.1 35.1-110.1 40-120.4
    Sensible Heat kW 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92
    Rated Cooling Capacity kW 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.3
    Scroll Compressor












    Standard Quantity n.° 1 1 1 1 1 1 2 2 2 2 2 2
    Operating Range Hz 30-100 30-100 30-100 30-100 30-100 30-100 30-100 30-100 30-100 30-100 30-100 30-100 30-100
    Fan Parameters 3)












    Quantity n.° 1 1 1 1 1 1 2 2 2 2 2 2
    Airflow m³/h 7500 8500 9300 10000 10500 12500 16500 18500 20000 21000 23000 25100
    Static Pressure Pa 20-200 20-200 20-200 20-200 20-200 20-200 20-200 20-200 20-200 20-200 20-200 20-200
    Fan Power Consumption kW 1.0 1.1 1.3 1.4 1.6 1.6 2.2 2.8 3.2 3.8 4.4 4.4
    Steam Humidifier (Optional)












    Steam Output kg/h 5 5 5 5 5 5 13 13 13 13 13 13
    Rated Power kW 3.75 3.75 3.75 3.75 3.75 3.75 9.75 9.75 9.75 9.75 9.75 9.75
    Rated Current A 6 6 6 6 6 6 15 15 15 15 15 15
    Electric Heater (Optional)












    Power kW 6 6 6 6 6 9 9 12 12 12 12 12
    Number of Stages n.° 1 1 1 1 1 2 2 3 3 3 3 3
    Current A 6.0 6.0 6.0 6.0 6.0 14.0 19.0 19.0 19.0 19.0 19.0 19.0
    Dimensions and Weight












    Length mm 925 1325 1325 1525 1525 1525 2200 2200 2400 2400 2400 2400
    Width mm 990 990 990 990 990 990 990 990 990 990 990 990
    Height mm 1975 1975 1975 1975 1975 1975 1975 1975 1975 1975 1975 1975
    Weight kg 410 475 481 505 510 515 632 728 733 753 775 788
    Electrical Parameters 3)












    Power Supply














    380V-50Hz-3F+N+PE 380V-50Hz-3F+N+PE 380V-50Hz-3F+N+PE 380V-50Hz-3F+N+PE 380V-50Hz-3F+N+PE 380V-50Hz-3F+N+PE 380V-50Hz-3F+N+PE 380V-50Hz-3F+N+PE 380V-50Hz-3F+N+PE 380V-50Hz-3F+N+PE 380V-50Hz-3F+N+PE
    Full Load Current A 36 40 42 45 50 65 76 84 91 101 111 121
    Recommended Circuit Breaker A 40 50 50 63 63 80 100 100 125 125 125 125
    Recommended Indoor Machine Cable mm² 3×10+2×6 3×10+2×6 3×10+2×6 3×10+2×6 3×10+2×6 3×16+2×10 3×16+2×10 3×25+2×16 3×25+2×16 3×25+2×16 3×25+2×16 3×25+2×16
    Recommended Outdoor Machine Cable mm² 3×1.5 3×1.5 3×1.5 3×1.5 3×2.5 3×2.5 3×2.5 3×2.5 3×2.5 3×2.5 3×2.5 3×2.5
    Air-Cooled Condenser












    RCS.A
    1×58 1×66 1×74 1×83 1×89 1×112 2×66 2×74 2×83 2×89 2×96 2×112
    RCSM.DUA
    1×58 1×66 1×74 1×83 1×89 1×112 2×66 2×74 2×83 2×89 2×96 2×112
    Notes:
    1. Indoor return air conditions: 35°C-26%RH, outdoor conditions: 35°C, annual energy efficiency ratio for outdoor conditions as per national standard conditions.
    2. Indoor return air conditions: 24°C-50%RH, outdoor conditions: 35°C, annual energy efficiency ratio for outdoor conditions as per national standard conditions.
    3. Fan specifications designed for G4 filter configuration, standard air supply volume.
    4. Maximum current includes heating and humidification, RCS series outdoor unit, electrical specifications for reference only. For other requirements, please contact the manufacturer.
    5. Steam humidifier and heater specifications are optional. For more details, please contact the manufacturer.
    6. If the required data is not listed, please contact the manufacturer.